Email :David@battery-equipments.com
FAQ
PRODUCTS LIST
products

5V6A 8 Channels Lithium Ion Battery Charge and Discharge Analyzer Machine

  • Model Number:

    TMAX-5V6A8CH
  • Compliance:

    CE certificate
  • Warranty:

    Two Year Limited Warranty With Lifetime Support
  • Payment:

    T/T, Credit Card, Paypal, LC, Western Union
  • Delivery Time:

    3 Days
contact now
Email:David@battery-equipments.com
Wechat:13506084915
DESCRIPTION

5V6A 8 Channels Lithium Ion Battery Charge and Discharge Analyzer Machine


Technical parameters

Indicator items

Indicator parameters

Equipment model

TMAX-5V6A8CH

Equipment specifications

5V/6A

Number of device channels

8

Channel control mode

Independent control for each channel, current and voltage four wire system acquisition

Channel characteristics

The constant current source and constant voltage source adopt a dual closed-loop structure

Input impedance

1M Ω

 

Current

Current range

Charge

10mV-5V (device port)

Discharge

0.75V-5V (device port), minimum discharge voltage depends on line length

Accuracy

±0.05% of FS, RT 15℃-35℃

 

voltage

Voltage range

Charge

0.02A-6A

Discharge

0.02A-6A

Accuracy

±0.05% of FS , RT 15℃-35℃

 

Power 

Single channel output power

30W

Stability

0.2% of FS

Time

Current response time

≤10ms

Data record

Recording frequency

1Hz

 

Data recording conditions

Minimum time interval: 1s

Minimum voltage interval: 1mV

Minimum current interval: 1mA

Charge

Charging mode

Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging

Deadline conditions

Voltage, current, relative time, capacity, - V

discharge

Discharge mode

Constant current discharge, constant power discharge, constant resistance discharge

Deadline conditions

Voltage, current, relative time, capacity, - V

Pulse mode

Optional

charging

Constant current mode, constant power mode

discharge

Constant current mode, constant power mode

Minimum pulse width

Suggest 5S or above

Deadline conditions

Voltage, relative time

 

Indicator items

Indicator parameters

DCIR

DCIR (optional)

Support custom point extraction for DCIR calculation

Cycle

Loop testing

Can set 399 commands and 65535 cycles

loop nesting

Supports 5-layer loop nesting

 

 

Protection

 

 

software protection

Support for power-off data protection

Support continuous startup (with UPS power supply)

Over voltage protection, under voltage protection, capacity protection, over current protection, under current protection

Anti reverse connection protection

Data export method

ExcelPDF

Cooling method

Air cooling

Equipment noise

≤50dB

Communication method with upper computer

Network

Overall dimensions

L450*W500*H140mm

display screen

 

system requirements

Windows XP and above

 

Environment requirements

Indicator items

Indicator parameters

Operating temperature range

0℃-40℃

Storage temperature range

-10℃-50℃

Relative humidity of working environment

70% RH (without water vapor condensation)

Relative humidity of storage environment

80% RH (without water vapor condensation)

Input active power

500W

Input power supply

AC220V ± 10%/50Hz, other power specifications available

Fixture type

Selection of upper and lower thimble fixtures and polymer fixtures

Other requirements

 

 



 

 battery equipment