- Battery Manufacturing Equipment
- Battery Laboratory Assembly Equipment
- Battery Pack Assembly Equipment
- Sodium Ion Battery Manufacturing Equipment
- Solid State Battery Assembly Line
- Dry Electrode Assembly Equipment
- Supercapacitor Assembly Equipment
- Perovskite Solar Cell Lab Equipment
- Li ion Battery Materials
- Ni / Al / Cu Metal Foam
- Customized Electrode
- Cathode Active Materials
- Anode Active Materials
- Coin Cell Parts
- Lithium Chip
- Cylindrical Cell Parts
- Battery Current Collectors
- Battery Conductive Materials
- Electrolyte
- Battery Binder
- Separator and Tape
- Aluminum Laminate Film
- Nickel Strip/Foil
- Battery Tabs
- Graphene Materials
- Cu / Al / Ni / Stainless steel Foil
- Battery Laboratory Equipment
- Li ion Battery Tester
- Battery Safety Tester
- Battery Material Tester
- Film Coating Machine
- Rolling Press Machine
- Electrode Mixer
- Coin Cell Crimping Machine
- Coin Cell Electrode Disc Punching
- Pouch Cell Sealing Machine
- Pouch Cell Stacking Machine
- Pouch Cell Forming Machine
- Pouch Cell Ultrasonic Welder
- Pouch Cell Electrode Die Cutter
- Cylinder Cell Sealing Machine
- Cylinder Cell Grooving Machine
- Electrode Slitting Machine
- Cylinder Cell Winding Machine
- Cylinder Cell Spot Welding Machine
- Electrolyte Filling
- Type Test Cell
- Other Battery Making Machine
- NMP Solvent Treatment System
- Vacuum Glove Box
- Lab Furnaces
- Ball Mill
- Hydraulic Press
- Laboratory Equipment
1100℃ Laboratory Mini Muffle Furnace Box Furnace
Model Number:
TMAX-KF1100-ICompliance:
CE certificateWarranty:
Two Year Limited Warranty With Lifetime SupportPayment:
T/T, Credit Card, Paypal, LC, Western UnionDelivery Time:
3 Days
Wechat:13506084915
1100℃ Laboratory Mini Muffle Furnace Box Furnace
Box type resistance furnace, also known as muffle furnace, is the basic heating equipment in laboratory. It is widely used in industrial and mining enterprises, aviation and aerospace systems, scientific research institutes, colleges and universities and other laboratories. It is a necessary instrument for material sintering, melting, heat treatment, volatilization and other experiments
Specification
Model |
KF1100-I |
Power |
1200W |
Chamber size (DXWXH, mm) |
100X100X100(LXWXH) |
Dimensions (WXDXH) |
220X270X380mm(LXWXH)
|
Voltage |
220V |
Phase |
Single phase |
Heating element |
Sweden Kanthal A1 imported resistance wire (resistance wire can be guaranteed for 2 years) |
Controller |
30-segment program temperature control 1. 30-stage program temperature control intelligent PID adjustment. 2. With over-temperature protection, the electric furnace heating circuit is automatically cut off when the temperature is over-temperature or broken, (when the electric furnace temperature exceeds 1200 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected, the main circuit is broken. On, the ON light on the panel is off, the OFF light is on, and the limited protection electric furnace). 3. With 485 communication interface (standard when purchasing software) 4. With power-off protection function, that is, when the power is turned on after the power is turned off, the program does not start from the starting temperature, but the furnace temperature rises from the time of power failure. 5. The meter has the function of temperature self-tuning
|
Temperature control mode |
Intelligent PID |
Over temperature protection |
Yes |
Overcurrent protection |
Yes |
Burnout protection and display |
Yes |
Furnace volume |
1L |
Furnace material |
1. High-quality and high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration. 2. Molded with Japanese technology. 3. The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software |
control accuracy |
+/- 1 ℃ |
maximum temperature |
1100 ℃ |
Rated temperature |
1000 ℃ |
Thermocouple model |
K Type |
Thyristor |
Triac |
surface temperature |
≤45℃ |
Warranty |
One year warranty, lifetime technical support Especially, the consumables such as heating element and sample crucible are not covered by the warranty Damage caused by the use of corrosive gases is not covered by the warranty |
Note |
1. For safety, please put the stove in a ventilated place. 2. In order to improve the service life of the furnace, we recommend that the heating rate should not exceed 10°C/min. The cooling rate does not exceed 5°C/min. 3. The furnace has no vacuum tightness, and it is forbidden to pass toxic or explosive gases 4. It is forbidden to put the materials directly on the bricks at the bottom of the furnace, please put the materials in the special crucible. 5. When heating, the materials and crucible should not touch the heating element and thermocouple 6. When not in use for a long time, please use the oven again. |