DESCRIPTION

40T Lab Manual Hydraulic Press Machine


The powder tablet press can be used in sample preparation with calcium-iron analyzer, Fourier infrared spectrometer (IR), X-ray fluorescence spectrometer (XRF) and other analytical testing instruments; it has been widely used in scientific research, teaching, testing, catalysis, pharmaceuticals, and chemical industries. In addition, various powder materials such as potassium bromide (KBr), sodium chloride (NaCl), boric acid (H3BO3) and other powder materials can be pressed into shapes through specific tableting molds, and various types of For scientific research on specimens, cylinders, special-shaped bodies or other shapes; at the same time, the hydraulic press is also suitable for other workplaces that require corresponding pressure. It is used as a press to test the pressure resistance of various objects, etc., and is widely used , Can replace similar imported products.


The SYP series laboratory manual tablet press is a new generation of compression molding machine developed by TMAX to meet the current market demand and accept the suggestions and feedback of some college teachers. The machine has the characteristics of beautiful appearance, compact structure, small size, fast pressing, simple operation, convenient cleaning, etc.; it adopts national utility model patent technology, one-piece structure, oil cylinder, oil pool, main board, and piston are all on one main body. The sealed connection reduces the oil leakage point and reduces the oil leakage rate of the tablet press; the imported pressure sensor is used to greatly improve the pressure stability; the future cleaning and maintenance work of the hydraulic press is considered at the beginning of the design, which is more convenient The user maintains the equipment and is deeply loved by users at home and abroad.

SYP-40C 40T hydraulic press is often used for sample preparation in laboratory fluorescence spectrometer, also known as fluorescence tablet press, equipped with appropriate X fluorescence special boric acid molds, steel ring molds, etc., can prepare test pieces required for fluorescence spectrometer testing. Compared with the SYP-40CS type manual tablet press, the main difference of this model is that the SYP-40C adopts a pointer type double-scale pressure gauge. The pressure and pressure are double-scaled. The applied pressure does not need to be converted to avoid mold overpressure. Other parameters are the same as SYP. -40CS type. Imported pressure sensor is used. For precise control of pressure, an "S" type digital pressure gauge can be selected, with a display accuracy of 0.01 MPa, and the model is SYP-40CS; a protective "F" function can also be added, with a machine glass protective cover for operation It is safer and safer to use, the model is SYP-40CF.


Technical parameters

Model

SYP-40C

SYP-40CS

SYP-40CF

SYP-40CFS

Pressure gauge type

Pointer type

Digital display

Pointer type

Digital display

Standard pressure gauge

Pointer type, double scale display of pressure tonnage and pressure MPa

Optional digital display

Digital display 0.00-40.00MPa/0.01MPa (only "S" type)

Pressure range

0-40T(0-30MPa)

Pressure conversion

1T=0.75Mpa

Piston diameter

Chrome plated cylinder φ130mm

Max. Piston stroke

50mm

Pressurization mode

Manual pressurization

Pressure stability

≤1MPA/10Min

Mold pressure calculation formula

The area of the oil cylinder ÷ the area of the mold × the reading of the pressure gauge = the actual pressure of the mold (Mpa)

the whole frame

One-piece structure

Workstation diameter

Φ140mm

Number of columns

4 pillars

4 pillars

Protection function

/

With plexiglass protective cover

Column space

106×185mm(W*H)

126×185mm(W*H)

over dimension

295×215×500mm(L*W*H)

355×215×505mm(L*W*H)

Weight

76kg

89kg

Standard configuration

40T manual tablet press, mold option; "S" in the model is a digital pressure gauge; With "F" for plexiglass protective cover

Remarks: Some of the indicators are unique to TMAX, which can be customized or improved according to customer needs.


Pressure conversion table

Model No.

SYP-40C type powder tablet press pressure conversion table

 

Actual output pressure

Pressure gauge system pressure

Pressure gauge type

1 T

0.75 MPa

pressure gauge 

3 T

2.20 MPa

5 T

3.70 MPa

10 T

7.50 MPa

12 T

9.00 MPa

15 T

11.3 MPa

20 T

15.0 MPa

30 T

22.5 MPa

40 T

30.0 MPa

Pressure calculation formula

The area of the oil cylinder/the area of the mold × the reading of the pressure gauge = the actual pressure of the mold (Mpa)

Note

The system pressure (ie pressure gauge reading) should not exceed 30MPa=40T, otherwise it will affect the service life of the equipment



 